Insufficient mixing of material flow and water is a common fault in the use of dry shotcrete machine. What method should we take to deal with such a failure when using a dry shotcrete machine? Let's take a look at what we should do when such a failure occurs:

Reason 1 and troubleshooting method:

Reason: Water pressure is too low

Troubleshooting method: Check the water pressure (at least 0.3MPa at the nozzle)

Reason 2 and troubleshooting method:

Reason: The water inlet hole of the nozzle water ring is blocked

Troubleshooting method: Check the nozzle and clean it up, install a water filter if necessary